Our LPS System consists of high-quality fittings and installation components to maintain integrity, ideal for securing safety in diverse environments. Trust U-Protec for premium-quality LPS system that ensure reliable protection.
U-Protec LPS (Lightning Protection System) is a network of rods, conductors, and grounding systems designed to intercept lightning strikes and safely channel the immense electrical current to the earth, protecting people, buildings, and electronic equipment from fire, damage, and electrocution by providing a low-impedance path.
They protect lives, property, and infrastructure from lightning’s destructive force, preventing fires, structural damage, and electronic equipment destruction. By channelling electrical energy safely into the ground, LPS ensures operational continuity, reduces insurance costs, and keeps you compliant with safety norms. It’s like having a superhero shield against lightning strikes!
A Cross Connector is used to securely join four conductors at right angles, ensuring strong mechanical and electrical continuity in earthing and lightning protection systems. Made from corrosion-resistant materials for long-lasting performance
Straight connectors securely join two conductors or rods in line, ensuring strong mechanical strength, corrosion resistance, and reliable electrical continuity in earthing systems.
For equalizing temperature-related length changes & necessary on conductor lengths over 20 Meters from round conductor.
The universal rod clamp is specifically designed to accommodate earth rods, allowing it to be used with various types of ground rods, such as copper-clad steel rods, solid copper rods, or galvanized steel rods. This versatility ensures compatibility with different grounding systems.
Sturdy and precise clamp designed to hold materials at diagonal angles securely, providing stability and ease of use in assembly and fabrication tasks
To be securely embedded in concrete, ensuring a corrosion-resistant link to the earth termination system for both protective and functional equipotential bonding, such as connecting to the structural reinforcement of buildings.
Standing Seam Clamps are specially designed to allow installers to securely attach Lightning Protection Conductors to roofing sheets that feature Standing Seam construction.
The test link is mainly used to offer a temporary break in the connection to earth allowing the testing of an earth rod whilst disconnecting from the lightning protection system.
Conductors are essential for carrying electric current with high efficiency and minimal resistance. Available in various materials, they provide safe, reliable, and durable performance in electrical and earthing systems.